Changes for page Power controller
Last modified by Mathias Larsen on 2026/09/24 21:21
From version 10.1
edited by Mathias Larsen
on 2026/05/25 13:23
on 2026/05/25 13:23
Change comment:
There is no comment for this version
To version 8.1
edited by Mathias Larsen
on 2026/05/25 12:10
on 2026/05/25 12:10
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,7 +23,7 @@ 23 23 |17|PB1|PWM: enable Fan 1 24 24 |18|PB2|Input: V-sense 25 25 |19|VSSA|Voltage source: Ground 26 -|20|VREF|Voltage reference ( Internalvoltagerefferance)26 +|20|VREF|Voltage reference (connected to +3V3)?? 27 27 |21|VDDA|Voltage source: Power (+3V3) 28 28 |22|PB10|Digital output: LED 8 29 29 |23|VSS|Voltage source: Ground ... ... @@ -40,12 +40,12 @@ 40 40 |36|VDD|Voltage source: Power (+3V3) 41 41 |37|PA13|SWDIO 42 42 |38|PA14|SWCLK 43 -|40|PB3| Digital output:LED 344 -|41|PB4| Digital output:LED 445 -|42|PB5| Digital output:LED 546 -|43|PB6| Digital output:Enable Pump 147 -|44|PB7| Digital output:Enable Pump 248 -|45|PB8| Digital output:LED 643 +|40|PB3|LED 3 44 +|41|PB4|LED 4 45 +|42|PB5|LED 5 46 +|43|PB6|Enable Pump 1 47 +|44|PB7|Enable Pump 2 48 +|45|PB8|LED 6 49 49 |46|PB9|LED 7 50 50 |47|VSS|Voltage source: Ground 51 51 |48|VDD|Voltage source: Power (+3V3)