Changes for page Power controller

Last modified by Mathias Larsen on 2026/09/24 21:21

From version 2.2
edited by Mathias Larsen
on 2026/05/24 15:14
Change comment: There is no comment for this version
To version 5.1
edited by Mathias Larsen
on 2026/05/24 17:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,46 @@
1 -|=Pin|=
2 -| |
3 -| |
1 +|=Physical pin|=Electrical pin|=(((
2 +Description
3 +)))
4 +|1|VBAT|Power source from a backup battery if a RTC would be used (Connected to +3V3 in this case)
5 +|5|OSC_IN|Clock input (8MHz oscillator)
6 +|7|NRST|Negative reset which can be connected to a button (Connected to +3V3)
7 +|8|PA0|Current 6
8 +|9|PA1|Current 7
9 +|10|PA2|Current 5
10 +|11|PA3|Current 4
11 +|12|PA4|Current 3
12 +|13|PA5|Current 2
13 +|14|PA6|LED 9
14 +|15|PA7|LED 2
15 +|16|PB0|Current 8
16 +|17|PB1|PWM enable Fan
17 +|18|PB2|V-sense
18 +|19|VSSA|Voltage source: Ground
19 +|20|VREF|Voltage reference (connected to +3V3)
20 +|21|VDDA|Voltage source: Power (+3V3)
21 +|22|PB10|LED 8
22 +|23|VSS|Voltage source: Ground
23 +|24|VDD|Voltage source: Power (+3V3)
24 +|25|PB11|Current 1
25 +|26|PB12|Current 9
26 +|29|PB15|PWM fan
27 +|30|PA8|Enable buzzeer
28 +|31|PA9|Enable buzzer
29 +|32|PA10|ASMS signal
30 +|33|PA11|CAN bus RXD
31 +|34|PA12|CAN bus TXD
32 +|35|VSS|Voltage source: Ground
33 +|36|VDD|Voltage source: Power (+3V3)
34 +|37|PA13|SWDIO
35 +|38|PA14|SWCLK
36 +|40|PB3|LED 3
37 +|41|PB4|LED 4
38 +|42|PB5|LED 5
39 +|43|PB6|Enable Pump 1
40 +|44|PB7|Enable Pump 2
41 +|45|PB8|LED 6
42 +|46|PB9|LED 7
43 +|47|VSS|Voltage source: Ground
44 +|48|VDD|Voltage source: Power (+3V3)
4 4  