Changes for page Power controller
Last modified by Mathias Larsen on 2026/09/24 21:21
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -255,26 +255,35 @@ 255 255 256 256 257 257 258 -= AR27 plan =258 += AR27 Concept = 259 259 260 -Here is the documentaionfor AR27260 +Here is the for AR27 261 261 262 262 == Changes == 263 263 264 -* More circuits 265 -* Autonomous supplied by ASMS 266 -** Rule requierment 267 -* 3 smaler 12V supply 268 -** Pump1 269 -** Pump2 270 -** Inverter/ other 12Vsupply 264 +* Circuits 265 +** more dedicate supply circuits 266 +** Keep the same current 267 +** Adjust the signal led resistor on the PCB 268 +* Digital signals 269 +** Adjust the signal led resistor on the PCB 270 +* 12V supply 271 +** 3 seprate 12 V supply 272 +*** Pump1 273 +*** Pump2 274 +*** Inverter/ other 12Vsupply 275 +* Autonomous 276 +** Supplied by ASMS 277 +** Potentially control ASSI 271 271 272 272 == Supply table == 273 273 274 -== Standard supply table == 281 +=== Standard supply table === 275 275 276 - == Autonomous supply table ==283 + 277 277 285 +=== Autonomous supply table === 286 + 278 278 == Relevant rules == 279 279 280 280 |=(% style="width: 472px;" %)Rule number|=(% style="width: 650px;" %)Rule