Content
... ... @@ -293,9 +293,28 @@
293 293  
294 294  === Standard supply table ===
295 295  
296 -|= |= |=
297 -| | |
298 -| | |
296 +|= |=Voltage|=Common power|=
297 +|IPC|24V|standalone|
298 +|Pumps|12V|standalone|
299 +|Fans|24V|standalone|
300 +|HVbox|24V|standalone|
301 +|Energy meter|12V|inverter, Energy meter telemetri|
302 +|Inverterx|12V |inverter, Energy meter telemetri|
303 +|Accumulator|24V|Standalone|
304 +|Brake light|24V|Standalone|
305 +|buzzer|24V|Standalone|
306 +|Sensor module R|24V| |
307 +|Sensor moduleF|24V| |
308 +|Tire temp|12V| |
309 +|Telemetrie|12V|inverter, Energy meter telemetri|
310 +|telemetri|24V| |
311 +|(((
312 +Dashboard
313 +)))|24V| |
314 +|SDC|24V| |
315 +|SDC monitor |24V| |
316 +|internal circuitry | | |
317 +| | | |
299 299  
300 300  === Autonomous supply table ===
301 301  
... ... @@ -303,9 +303,9 @@
303 303  |Steering motor |1|?
304 304  |(((
305 305  ASB/ESB
306 -)))| |
307 -|ASSI| |
308 -| | |
325 +)))| |?
326 +|ASSI|2|?
327 +|RES|1|?
309 309  