Changes for page Power controller

Last modified by Mathias Larsen on 2026/09/24 21:21

From version 7.2
edited by Mathias Larsen
on 2026/05/25 12:05
Change comment: There is no comment for this version
To version 7.1
edited by Mathias Larsen
on 2026/05/25 11:55
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,12 +11,12 @@
11 11  |1|VBAT|Power source from a backup battery if a RTC would be used (Connected to +3V3 in this case)
12 12  |5|OSC_IN|Clock input (8MHz oscillator)
13 13  |7|NRST|Negative reset which can be connected to a button (Connected to +3V3)
14 -|8|PA0|Analog signal: Current 6 Supply 24V resserve
15 -|9|PA1|Analog signal: Current 7 Supply 24V resserve
16 -|10|PA2|Analog signal: Current 5 Supply sensor card
17 -|11|PA3|Analog signal: Current 4 Supply front
18 -|12|PA4|Analog signal: Current 3 Supply accumulator
19 -|13|PA5|Analog signal: Current 2 Supply fans
14 +|8|PA0|Current 6 Supply 24V resserve
15 +|9|PA1|Current 7 Supply 24V resserve
16 +|10|PA2|Current 5 Supply sensor card
17 +|11|PA3|Current 4 Supply front
18 +|12|PA4|Current 3 Supply accumulator
19 +|13|PA5|Current 2 Supply fans
20 20  |14|PA6|LED 9
21 21  |15|PA7|LED 2
22 22  |16|PB0|Current 8 Supply buzzer, brake light