Changes for page Sensor Module
Last modified by Heimir Thordarson on 2026/07/05 12:56
From version 11.5
edited by Heimir Thordarson
on 2026/01/21 13:59
on 2026/01/21 13:59
Change comment:
There is no comment for this version
To version 12.6
edited by Mads Pedersen
on 2026/01/21 14:35
on 2026/01/21 14:35
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.1 173493302473695372121 +XWiki.100704191293964212740 - Content
-
... ... @@ -19,11 +19,30 @@ 19 19 20 20 In the figure above, the pinout shows how the pins are divided. Each box shows which pins belong together for each usecase, where the red box is the power input. Yellow boxes are for each canbus network, while the green box is for each sensor used in AR26. 21 21 22 -|=Pin Number|=((( 22 + 23 +(% style="width:432px" %) 24 +|=(% style="width: 97px;" %)Pin Number|=(% style="width: 216px;" %)Pin Name|=(% style="width: 116px;" %)Type 25 +|(% style="width:97px" %)((( 23 23 1 24 -)))|=2|=3|=4|=5|=6|=7|=8|=9|= |= |= |= |= |= 25 -|Pin Name| | | | | | | | | | | | | | | 27 +)))|(% style="width:216px" %)Air Temperature|(% style="width:116px" %)Analog (0-3.3V) 28 +|(% style="width:97px" %)2|(% style="width:216px" %)Suspension Displacement Left|(% style="width:116px" %)Analog (0-3.3V) 29 +|(% style="width:97px" %)3|(% style="width:216px" %)Suspension Displacement Right|(% style="width:116px" %)Analog (0-3.3V) 30 +|(% style="width:97px" %)4|(% style="width:216px" %)Oil Temperature Right|(% style="width:116px" %)Analog (0-3.3V) 31 +|(% style="width:97px" %)5|(% style="width:216px" %)Oil Temperature Left|(% style="width:116px" %)Analog (0-3.3V) 32 +|(% style="width:97px" %)6|(% style="width:216px" %)Cooling Temperature 4|(% style="width:116px" %)Analog (0-3.3V) 33 +|(% style="width:97px" %)7|(% style="width:216px" %)Cooling Pressure 4|(% style="width:116px" %)Analog (0-5V) 34 +|(% style="width:97px" %)8|(% style="width:216px" %)Cooling Temperature 3|(% style="width:116px" %)Analog (0-3.3V) 35 +|(% style="width:97px" %)9|(% style="width:216px" %)Cooling Pressure 3|(% style="width:116px" %)Analog (0-5V) 36 +|(% style="width:97px" %)10|(% style="width:216px" %)Cooling Temperature 2|(% style="width:116px" %)Analog (0-3.3V) 37 +|(% style="width:97px" %)11|(% style="width:216px" %)Cooling Pressure 2|(% style="width:116px" %)Analog (0-5V) 38 +|(% style="width:97px" %)12|(% style="width:216px" %)Cooling Temperature 1|(% style="width:116px" %)Analog (0-3.3V) 39 +|(% style="width:97px" %)13|(% style="width:216px" %)Cooling Pressure 1|(% style="width:116px" %)Analog (0-5V) 40 +|(% style="width:97px" %)14|(% style="width:216px" %)CAN High 1|(% style="width:116px" %)CAN-BUS 41 +|(% style="width:97px" %)15|(% style="width:216px" %)CAN Low 1|(% style="width:116px" %)CAN-BUS 26 26 43 +/htm 44 + 45 + 27 27 == Typical Application == 28 28 29 29 = Design =