Changes for page Sensor Module
Last modified by Heimir Thordarson on 2026/07/05 12:56
From version 16.10
edited by Heimir Thordarson
on 2026/01/22 11:07
on 2026/01/22 11:07
Change comment:
There is no comment for this version
To version 16.11
edited by Heimir Thordarson
on 2026/01/22 11:08
on 2026/01/22 11:08
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,7 +61,7 @@ 61 61 62 62 === Air Temperature Sensor === 63 63 64 -The air temperature sensor will be used to have a dynamic reference setpoint for the cooling system. This could reduce the current draw from the low voltage system compared to having a fixed reference point. This is because the regulator will not try to cool the water to a temperature lower than the ambient temperature. The sensor works as a resistor which varies depending on its temperature. Where in this case, the resistance lowers when the temperature increases () 64 +The air temperature sensor will be used to have a dynamic reference setpoint for the cooling system. This could reduce the current draw from the low voltage system compared to having a fixed reference point. This is because the regulator will not try to cool the water to a temperature lower than the ambient temperature. The sensor works as a resistor which varies depending on its temperature. Where in this case, the resistance lowers when the temperature increases (NTC). To make the microcontroller able to measure the changes in resistance, the thermistor is put into a voltage divider circuit. 65 65 66 66 ==== Analog to Digital Converter ==== 67 67