Changes for page Sensor Module

Last modified by Heimir Thordarson on 2026/07/05 12:56

From version 37.1
edited by Heimir Thordarson
on 2026/01/26 17:19
Change comment: There is no comment for this version
To version 39.3
edited by Heimir Thordarson
on 2026/01/26 17:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -95,5 +95,22 @@
95 95  {{/mathjax}}
96 96  )))
97 97  
98 -* {{mathjax}}\(\beta\){{/mathjax}} = material constant that defines the steepness of its resistance-temperature curve between two temperature points, usually 25/85 degrees celsius. In this case it is 3694 //**K**//
99 -* //{{mathjax}}\(T_0\){{/mathjax}} =//
98 +where:
99 +
100 +* {{mathjax}}\(\beta\){{/mathjax}} = material constant that defines the steepness of its resistance-temperature curve between two temperature points, usually 25/85 degrees celsius. In this case it is 3694 //**K.**//
101 +* {{mathjax}}\(T_0\){{/mathjax}} = The test temperature at which the thermistor is 10k {{mathjax}}\(\Omega\){{/mathjax}}, which in this case is 25 degrees celsius.
102 +* {{mathjax}}\(R_0\){{/mathjax}} = The resistance of the thermistor when it is 25 degrees celsius.
103 +* {{mathjax}}\(R_T\){{/mathjax}} = The current resistance of the thermistor.
104 +
105 +==== Filtering ====
106 +
107 +Considering that the sensor can only promise a reaction time of 5 seconds when in water, it can be assumed that a heavy filter will not add any problematic latencies. To ensure a low cost, the filter uses common components which will filter any noise above the inverter switching noise.
108 +
109 +(% style="font-size: 1.5em;" %)
110 +(((
111 +{{mathjax}}
112 +$$
113 +T = \frac{1}{2 \pi R C}
114 +$$
115 +{{/mathjax}}
116 +)))