... ... @@ -115,7 +115,7 @@
115 115  * {{mathjax}}\(R\){{/mathjax}} = Resistance of the resistor in low-pass filter.
116 116  * {{mathjax}}\(C\){{/mathjax}} = Capacitance of the capacitor in the low-pass filter.
117 117  
118 -Using a resistor with 1k {{mathjax}}\(\Omega\){{/mathjax}} and a capacitor with 100 **nF **in capacitance, the cut-off frequency will be 1592 **Hz.**
118 +Using a resistor with 10k {{mathjax}}\(\Omega\){{/mathjax}} and a capacitor with 100 **nF **in capacitance, the cut-off frequency will be 159 **Hz.**
119 119  
120 120  == Suspension Displacement Sensor ==
121 121  
... ... @@ -129,21 +129,6 @@
129 129  
130 130  This can then be used to create the length of the sensor based on the input voltage.
131 131  
132 -(% style="font-size: 1.5em;" %)
133 -(((
134 -{{mathjax}}
135 -$$
136 -x = \frac{50}{1960} \left( \frac{2000\,V_{\text{out}}}{V_s} - 20 \right)
137 -$$
138 -{{/mathjax}}
139 -)))
140 140  
141 -where:
142 142  
143 -* {{mathjax}}\(x\){{/mathjax}} = The mechanical placement excluding the dead length.
144 -* {{mathjax}}\(V_s\){{/mathjax}} = The supply voltage of the linear potentiometer, in this case it is 3.3 {{mathjax}}\(V\){{/mathjax}}.
145 -* {{mathjax}}\(V_{out}\){{/mathjax}} = The output voltage of the linear potentiometer. ranging from 0.033{{mathjax}}\(V\){{/mathjax}} to 3.267{{mathjax}}\(V\){{/mathjax}}.
146 -
147 -=== Filtering ===
148 -
149 -The sensors output latency can be expected to be a lot shorter than the air temperature sensor as the sensor is just a variable sensor based on placement. The limiting
134 +