Summary

Details

Page properties
Content
... ... @@ -161,6 +161,6 @@
161 161  
162 162  The sensors output latency can be expected to be a lot shorter than the air temperature sensor as the sensor is just a variable sensor based on placement. The limiting factor for the system which uses this information is the CAN-BUS messages from the inverters which send the information each 6.25 milliseconds. This means that the cut-off frequency cannot be any lower than 160 Hz, which will make the same type of low pass filter from the air temperature sensor acceptable with a cut-off frequency of 1591 Hz.
163 163  
164 -== Cooling Sensors ==
164 +== Gearbox Temperature Sensor ==
165 165  
166 -The cooling sensors for the AR26 can is the
166 +The gearbox Temperature Sensor for AR26 will be the