... ... @@ -24,7 +24,7 @@
24 24  
25 25  The Sensor module is designed to measure any extra analog signals rear of the firewall. For AR26, the module is designed to measure two suspension displacement sensors, two oil temperature, four water pressure, four water temperature, and one air temperature sensor. All of the measurements are then transmitted to a CAN network, which there are two of.
26 26  
27 -= Wiring Diagram =
27 += Design =
28 28  
29 29  In the following section, how the sensor module is connected will be covered. The connector for the sensor module is a [[High-Density d'sub-44>>https://www.te.com/en/product-2311770-1.html]] which is directly solderen onto the circuit board. The plug needed for this system is the [[204517-3>>doc:Sandbox.TestPage3]], which uses crimps instead of solder cups which is common for the dsub connectors
30 30  
... ... @@ -66,6 +66,47 @@
66 66  |(% style="width:71px" %)14|(% style="width:164px" %)CAN High 1|(% style="width:124px" %)CAN|(% style="width:70px" %)29|(% style="width:218px" %)CAN Low 2|(% style="width:58px" %)CAN|(% style="width:32px" %)44|(% style="width:192px" %)Main Power|(% style="width:90px" %)+24V
67 67  |(% style="width:71px" %)15|(% style="width:164px" %)CAN Low 1|(% style="width:124px" %)CAN|(% style="width:70px" %)30|(% style="width:218px" %)CAN High 2|(% style="width:58px" %)CAN|(% style="width:32px" %) |(% style="width:192px" %) |(% style="width:90px" %)
68 68  
69 +== Microcontroller Pinout ==
70 +
71 +(% style="width:793.6px" %)
72 +|=(% style="width: 96px;" %)Physical Pin|=(% style="width: 102px;" %)Electrical Pin|=(% style="width: 593px;" %)Description
73 +|(% style="width:96px" %)1|(% style="width:102px" %)VBAT|(% style="width:593px" %)Power source from a backup battery if a RTC would be used (Connected to +3V3 in this case)
74 +|(% style="width:96px" %)5|(% style="width:102px" %)OSC_IN|(% style="width:593px" %)Clock input (8MHz oscillator)
75 +|(% style="width:96px" %)7|(% style="width:102px" %)NRST|(% style="width:593px" %)Negative reset which can be connected to a button (Connected to +3V3)
76 +|(% style="width:96px" %)9|(% style="width:102px" %)PC1|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 2
77 +|(% style="width:96px" %)10|(% style="width:102px" %)PC2|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 2
78 +|(% style="width:96px" %)11|(% style="width:102px" %)PC3|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 4
79 +|(% style="width:96px" %)12|(% style="width:102px" %)PA0|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 4
80 +|(% style="width:96px" %)13|(% style="width:102px" %)PA1|(% style="width:593px" %)Analog signal: Oil temperature sensor right
81 +|(% style="width:96px" %)14|(% style="width:102px" %)PA2|(% style="width:593px" %)Analog signal: Air temperature sensor
82 +|(% style="width:96px" %)15|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
83 +|(% style="width:96px" %)16|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
84 +|(% style="width:96px" %)17|(% style="width:102px" %)PA3|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 1
85 +|(% style="width:96px" %)18|(% style="width:102px" %)PA4|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 1
86 +|(% style="width:96px" %)19|(% style="width:102px" %)PA5|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 3
87 +|(% style="width:96px" %)20|(% style="width:102px" %)PA6|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 3
88 +|(% style="width:96px" %)21|(% style="width:102px" %)PA7|(% style="width:593px" %)Analog signal: Oil temperature sensor left
89 +|(% style="width:96px" %)22|(% style="width:102px" %)PC4|(% style="width:593px" %)Analog signal: Suspension displacement sensor right
90 +|(% style="width:96px" %)23|(% style="width:102px" %)PC5|(% style="width:593px" %)Analog signal: Suspension displacement sensor left
91 +|(% style="width:96px" %)27|(% style="width:102px" %)VSSA|(% style="width:593px" %)Voltage source: Ground
92 +|(% style="width:96px" %)28|(% style="width:102px" %)VREF+|(% style="width:593px" %)Voltage reference (connected to +3V3)
93 +|(% style="width:96px" %)29|(% style="width:102px" %)VDDA|(% style="width:593px" %)Voltage source: Power (+3V3)
94 +|(% style="width:96px" %)31|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
95 +|(% style="width:96px" %)32|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
96 +|(% style="width:96px" %)34|(% style="width:102px" %)PB12|(% style="width:593px" %)CAN-BUS 2: Rxd
97 +|(% style="width:96px" %)35|(% style="width:102px" %)PB13|(% style="width:593px" %)CAN-BUS 2: Txd
98 +|(% style="width:96px" %)38|(% style="width:102px" %)PC6|(% style="width:593px" %)Signal Output: Blue status LED
99 +|(% style="width:96px" %)45|(% style="width:102px" %)PA11|(% style="width:593px" %)CAN-BUS 2: Rxd
100 +|(% style="width:96px" %)46|(% style="width:102px" %)PA12|(% style="width:593px" %)CAN-BUS 2: Txd
101 +|(% style="width:96px" %)47|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
102 +|(% style="width:96px" %)48|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
103 +|(% style="width:96px" %)49|(% style="width:102px" %)PA13|(% style="width:593px" %)Programming Pins: SWDIO
104 +|(% style="width:96px" %)50|(% style="width:102px" %)PA14|(% style="width:593px" %)Programming Pins: SWCLK
105 +|(% style="width:96px" %)63|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
106 +|(% style="width:96px" %)64|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
107 +
108 +
109 +
69 69  == Air Temperature Sensor ==
70 70  
71 71  The air temperature sensor will be used to have a dynamic reference setpoint for the cooling system. This could reduce the current draw from the low voltage system compared to having a fixed reference point. This is because the regulator will not try to cool the water to a temperature lower than the ambient temperature. The sensor works as a resistor which varies depending on its temperature. Where in this case, the resistance lowers when the temperature increases (NTC). To make the microcontroller able to measure the changes in resistance, the thermistor is put into a voltage divider circuit.
... ... @@ -207,4 +207,12 @@
207 207  
208 208  The sensors output latency can be expected to be a lot shorter than the oil temperature sensor as the sensor is just a variable sensor based on placement. The limiting factor for the system which uses this information is the CAN-BUS messages from the inverters which send the information each 6.25 milliseconds. This means that the cut-off frequency cannot be any lower than 160 Hz, which will make the same type of low pass filter from the oil temperature sensor acceptable with a cut-off frequency of 1591 Hz.
209 209  
251 += Bill of Materials =
252 +
253 +== Circuit Board ==
254 +
255 +== Wiring Harness ==
256 +
257 +== Sensors ==
258 +
210 210