Changes for page Sensor Module
Last modified by Heimir Thordarson on 2026/07/05 12:56
From version 61.1
edited by Heimir Thordarson
on 2026/02/23 17:37
on 2026/02/23 17:37
Change comment:
There is no comment for this version
To version 63.1
edited by Heimir Thordarson
on 2026/02/23 18:01
on 2026/02/23 18:01
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -68,8 +68,45 @@ 68 68 69 69 == Microcontroller Pinout == 70 70 71 +(% style="width:793.6px" %) 72 +|=(% style="width: 96px;" %)Physical Pin|=(% style="width: 102px;" %)Electrical Pin|=(% style="width: 593px;" %)Description 73 +|(% style="width:96px" %)1|(% style="width:102px" %)VBAT|(% style="width:593px" %)Power source from a backup battery if a RTC would be used (Connected to +3V3 in this case) 74 +|(% style="width:96px" %)5|(% style="width:102px" %)OSC_IN|(% style="width:593px" %)Clock input (8MHz oscillator) 75 +|(% style="width:96px" %)7|(% style="width:102px" %)NRST|(% style="width:593px" %)Negative reset which can be connected to a button (Connected to +3V3) 76 +|(% style="width:96px" %)9|(% style="width:102px" %)PC1|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 2 77 +|(% style="width:96px" %)10|(% style="width:102px" %)PC2|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 2 78 +|(% style="width:96px" %)11|(% style="width:102px" %)PC3|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 4 79 +|(% style="width:96px" %)12|(% style="width:102px" %)PA0|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 4 80 +|(% style="width:96px" %)13|(% style="width:102px" %)PA1|(% style="width:593px" %)Analog signal: Oil temperature sensor right 81 +|(% style="width:96px" %)14|(% style="width:102px" %)PA2|(% style="width:593px" %)Analog signal: Air temperature sensor 82 +|(% style="width:96px" %)15|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground 83 +|(% style="width:96px" %)16|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3) 84 +|(% style="width:96px" %)17|(% style="width:102px" %)PA3|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 1 85 +|(% style="width:96px" %)18|(% style="width:102px" %)PA4|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 1 86 +|(% style="width:96px" %)19|(% style="width:102px" %)PA5|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 3 87 +|(% style="width:96px" %)20|(% style="width:102px" %)PA6|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 3 88 +|(% style="width:96px" %)21|(% style="width:102px" %)PA7|(% style="width:593px" %)Analog signal: Oil temperature sensor left 89 +|(% style="width:96px" %)22|(% style="width:102px" %)PC4|(% style="width:593px" %)Analog signal: Suspension displacement sensor right 90 +|(% style="width:96px" %)23|(% style="width:102px" %)PC5|(% style="width:593px" %)Analog signal: Suspension displacement sensor left 91 +|(% style="width:96px" %)27|(% style="width:102px" %)VSSA|(% style="width:593px" %)Voltage source: Ground 92 +|(% style="width:96px" %)28|(% style="width:102px" %)VREF+|(% style="width:593px" %)Voltage reference (connected to +3V3) 93 +|(% style="width:96px" %)29|(% style="width:102px" %)VDDA|(% style="width:593px" %)Voltage source: Power (+3V3) 94 +|(% style="width:96px" %)31|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground 95 +|(% style="width:96px" %)32|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3) 96 +|(% style="width:96px" %)34|(% style="width:102px" %)PB12|(% style="width:593px" %)CAN-BUS 2: Rxd 97 +|(% style="width:96px" %)35|(% style="width:102px" %)PB13|(% style="width:593px" %)CAN-BUS 2: Txd 98 +|(% style="width:96px" %)38|(% style="width:102px" %)PC6|(% style="width:593px" %)Signal Output: Blue status LED 99 +|(% style="width:96px" %)45|(% style="width:102px" %)PA11|(% style="width:593px" %)CAN-BUS 2: Rxd 100 +|(% style="width:96px" %)46|(% style="width:102px" %)PA12|(% style="width:593px" %)CAN-BUS 2: Txd 101 +|(% style="width:96px" %)47|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground 102 +|(% style="width:96px" %)48|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3) 103 +|(% style="width:96px" %)49|(% style="width:102px" %)PA13|(% style="width:593px" %)Programming Pins: SWDIO 104 +|(% style="width:96px" %)50|(% style="width:102px" %)PA14|(% style="width:593px" %)Programming Pins: SWCLK 105 +|(% style="width:96px" %)63|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground 106 +|(% style="width:96px" %)64|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3) 71 71 72 72 109 + 73 73 == Air Temperature Sensor == 74 74 75 75 The air temperature sensor will be used to have a dynamic reference setpoint for the cooling system. This could reduce the current draw from the low voltage system compared to having a fixed reference point. This is because the regulator will not try to cool the water to a temperature lower than the ambient temperature. The sensor works as a resistor which varies depending on its temperature. Where in this case, the resistance lowers when the temperature increases (NTC). To make the microcontroller able to measure the changes in resistance, the thermistor is put into a voltage divider circuit.