66 66  |(% style="width:71px" %)14|(% style="width:164px" %)CAN High 1|(% style="width:124px" %)CAN|(% style="width:70px" %)29|(% style="width:218px" %)CAN Low 2|(% style="width:58px" %)CAN|(% style="width:32px" %)44|(% style="width:192px" %)Main Power|(% style="width:90px" %)+24V
67 67  |(% style="width:71px" %)15|(% style="width:164px" %)CAN Low 1|(% style="width:124px" %)CAN|(% style="width:70px" %)30|(% style="width:218px" %)CAN High 2|(% style="width:58px" %)CAN|(% style="width:32px" %) |(% style="width:192px" %) |(% style="width:90px" %)
68 68  
69 -== Microcontroller Pinout ==
70 -
71 -(% style="width:793.6px" %)
72 -|=(% style="width: 96px;" %)Physical Pin|=(% style="width: 102px;" %)Electrical Pin|=(% style="width: 593px;" %)Description
73 -|(% style="width:96px" %)1|(% style="width:102px" %)VBAT|(% style="width:593px" %)Power source from a backup battery if a RTC would be used (Connected to +3V3 in this case)
74 -|(% style="width:96px" %)5|(% style="width:102px" %)OSC_IN|(% style="width:593px" %)Clock input (8MHz oscillator)
75 -|(% style="width:96px" %)7|(% style="width:102px" %)NRST|(% style="width:593px" %)Negative reset which can be connected to a button (Connected to +3V3)
76 -|(% style="width:96px" %)9|(% style="width:102px" %)PC1|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 2
77 -|(% style="width:96px" %)10|(% style="width:102px" %)PC2|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 2
78 -|(% style="width:96px" %)11|(% style="width:102px" %)PC3|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 4
79 -|(% style="width:96px" %)12|(% style="width:102px" %)PA0|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 4
80 -|(% style="width:96px" %)13|(% style="width:102px" %)PA1|(% style="width:593px" %)Analog signal: Oil temperature sensor right
81 -|(% style="width:96px" %)14|(% style="width:102px" %)PA2|(% style="width:593px" %)Analog signal: Air temperature sensor
82 -|(% style="width:96px" %)15|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
83 -|(% style="width:96px" %)16|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
84 -|(% style="width:96px" %)17|(% style="width:102px" %)PA3|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 1
85 -|(% style="width:96px" %)18|(% style="width:102px" %)PA4|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 1
86 -|(% style="width:96px" %)19|(% style="width:102px" %)PA5|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 3
87 -|(% style="width:96px" %)20|(% style="width:102px" %)PA6|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 3
88 -|(% style="width:96px" %)21|(% style="width:102px" %)PA7|(% style="width:593px" %)Analog signal: Oil temperature sensor left
89 -|(% style="width:96px" %)22|(% style="width:102px" %)PC4|(% style="width:593px" %)Analog signal: Suspension displacement sensor right
90 -|(% style="width:96px" %)23|(% style="width:102px" %)PC5|(% style="width:593px" %)Analog signal: Suspension displacement sensor left
91 -|(% style="width:96px" %)27|(% style="width:102px" %)VSSA|(% style="width:593px" %)Voltage source: Ground
92 -|(% style="width:96px" %)28|(% style="width:102px" %)VREF+|(% style="width:593px" %)Voltage reference (connected to +3V3)
93 -|(% style="width:96px" %)29|(% style="width:102px" %)VDDA|(% style="width:593px" %)Voltage source: Power (+3V3)
94 -|(% style="width:96px" %)31|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
95 -|(% style="width:96px" %)32|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
96 -|(% style="width:96px" %)34|(% style="width:102px" %)PB12|(% style="width:593px" %)CAN-BUS 2: Rxd
97 -|(% style="width:96px" %)35|(% style="width:102px" %)PB13|(% style="width:593px" %)CAN-BUS 2: Txd
98 -|(% style="width:96px" %)38|(% style="width:102px" %)PC6|(% style="width:593px" %)Signal Output: Blue status LED
99 -|(% style="width:96px" %)45|(% style="width:102px" %)PA11|(% style="width:593px" %)CAN-BUS 2: Rxd
100 -|(% style="width:96px" %)46|(% style="width:102px" %)PA12|(% style="width:593px" %)CAN-BUS 2: Txd
101 -|(% style="width:96px" %)47|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
102 -|(% style="width:96px" %)48|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
103 -|(% style="width:96px" %)49|(% style="width:102px" %)PA13|(% style="width:593px" %)Programming Pins: SWDIO
104 -|(% style="width:96px" %)50|(% style="width:102px" %)PA14|(% style="width:593px" %)Programming Pins: SWCLK
105 -|(% style="width:96px" %)63|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
106 -|(% style="width:96px" %)64|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
107 -
108 -
109 -
110 110  == Air Temperature Sensor ==
111 111  
112 112  The air temperature sensor will be used to have a dynamic reference setpoint for the cooling system. This could reduce the current draw from the low voltage system compared to having a fixed reference point. This is because the regulator will not try to cool the water to a temperature lower than the ambient temperature. The sensor works as a resistor which varies depending on its temperature. Where in this case, the resistance lowers when the temperature increases (NTC). To make the microcontroller able to measure the changes in resistance, the thermistor is put into a voltage divider circuit.