... ... @@ -68,47 +68,44 @@
68 68  
69 69  == Microcontroller Pinout ==
70 70  
71 -The sensor module uses a microcontroller to measure and calculate the values for the analog signals. The microcontroller used in this system is the [[STM32G491RET6>>doc:.https\:www\.st\.comenmicrocontrollers-microprocessorsstm32g491re\.html.WebHome]]
71 +|=(% style="width: 96px;" %)Physical Pin|=(% style="width: 102px;" %)Electrical Pin|=(% style="width: 991px;" %)Description
72 +|(% style="width:96px" %)1|(% style="width:102px" %)VBAT|(% style="width:991px" %)Power source from a backup battery if a RTC would be used (Connected to +3V3 in this case)
73 +|(% style="width:96px" %)5|(% style="width:102px" %)OSC_IN|(% style="width:991px" %)Clock input (8MHz oscillator)
74 +|(% style="width:96px" %)7|(% style="width:102px" %)NRST|(% style="width:991px" %)Negative reset which can be connected to a button (Connected to +3V3)
75 +|(% style="width:96px" %)9|(% style="width:102px" %)PC1|(% style="width:991px" %)Analog signal: Cooling pressure sensor number 2
76 +|(% style="width:96px" %)10|(% style="width:102px" %)PC2|(% style="width:991px" %)Analog signal: Cooling temperature sensor number 2
77 +|(% style="width:96px" %)11|(% style="width:102px" %)PC3|(% style="width:991px" %)Analog signal: Cooling pressure sensor number 4
78 +|(% style="width:96px" %)12|(% style="width:102px" %)PA0|(% style="width:991px" %)Analog signal: Cooling temperature sensor number 4
79 +|(% style="width:96px" %)13|(% style="width:102px" %)PA1|(% style="width:991px" %)Analog signal: Oil temperature sensor right
80 +|(% style="width:96px" %)14|(% style="width:102px" %)PA2|(% style="width:991px" %)Analog signal: Air temperature sensor
81 +|(% style="width:96px" %)15|(% style="width:102px" %)VSS|(% style="width:991px" %)Voltage source: Ground
82 +|(% style="width:96px" %)16|(% style="width:102px" %)VDD|(% style="width:991px" %)Voltage source: Power (+3V3)
83 +|(% style="width:96px" %)17|(% style="width:102px" %)PA3|(% style="width:991px" %)Analog signal: Cooling pressure sensor number 1
84 +|(% style="width:96px" %)18|(% style="width:102px" %)PA4|(% style="width:991px" %)Analog signal: Cooling temperature sensor number 1
85 +|(% style="width:96px" %)19|(% style="width:102px" %)PA5|(% style="width:991px" %)Analog signal: Cooling pressure sensor number 3
86 +|(% style="width:96px" %)20|(% style="width:102px" %)PA6|(% style="width:991px" %)Analog signal: Cooling temperature sensor number 3
87 +|(% style="width:96px" %)21|(% style="width:102px" %)PA7|(% style="width:991px" %)Analog signal: Oil temperature sensor left
88 +|(% style="width:96px" %)22|(% style="width:102px" %)PC4|(% style="width:991px" %)Analog signal: Suspension displacement sensor right
89 +|(% style="width:96px" %)23|(% style="width:102px" %)PC5|(% style="width:991px" %)Analog signal: Suspension displacement sensor left
90 +|(% style="width:96px" %)27|(% style="width:102px" %)VSSA|(% style="width:991px" %)Voltage source: Ground
91 +|(% style="width:96px" %)28|(% style="width:102px" %)VREF+|(% style="width:991px" %)Voltage reference (connected to +3V3)
92 +|(% style="width:96px" %)29|(% style="width:102px" %)VDDA|(% style="width:991px" %)Voltage source: Power (+3V3)
93 +|(% style="width:96px" %)31|(% style="width:102px" %)VSS|(% style="width:991px" %)Voltage source: Ground
94 +|(% style="width:96px" %)32|(% style="width:102px" %)VDD|(% style="width:991px" %)Voltage source: Power (+3V3)
95 +|(% style="width:96px" %)34|(% style="width:102px" %)PB12|(% style="width:991px" %)CAN-BUS 2: Rxd
96 +|(% style="width:96px" %)35|(% style="width:102px" %)PB13|(% style="width:991px" %)CAN-BUS 2: Txd
97 +|(% style="width:96px" %)38|(% style="width:102px" %)PC6|(% style="width:991px" %)Signal Output: Blue status LED
98 +|(% style="width:96px" %)45|(% style="width:102px" %)PA11|(% style="width:991px" %)CAN-BUS 2: Rxd
99 +|(% style="width:96px" %)46|(% style="width:102px" %)PA12|(% style="width:991px" %)CAN-BUS 2: Txd
100 +|(% style="width:96px" %)47|(% style="width:102px" %)VSS|(% style="width:991px" %)Voltage source: Ground
101 +|(% style="width:96px" %)48|(% style="width:102px" %)VDD|(% style="width:991px" %)Voltage source: Power (+3V3)
102 +|(% style="width:96px" %)49|(% style="width:102px" %)PA13|(% style="width:991px" %)Programming Pins: SWDIO
103 +|(% style="width:96px" %)50|(% style="width:102px" %)PA14|(% style="width:991px" %)Programming Pins: SWCLK
104 +|(% style="width:96px" %)63|(% style="width:102px" %)VSS|(% style="width:991px" %)Voltage source: Ground
105 +|(% style="width:96px" %)64|(% style="width:102px" %)VDD|(% style="width:991px" %)Voltage source: Power (+3V3)
72 72  
73 -(% style="width:793.6px" %)
74 -|=(% style="width: 96px;" %)Physical Pin|=(% style="width: 102px;" %)Electrical Pin|=(% style="width: 593px;" %)Description
75 -|(% style="width:96px" %)1|(% style="width:102px" %)VBAT|(% style="width:593px" %)Power source from a backup battery if a RTC would be used (Connected to +3V3 in this case)
76 -|(% style="width:96px" %)5|(% style="width:102px" %)OSC_IN|(% style="width:593px" %)Clock input (8MHz oscillator)
77 -|(% style="width:96px" %)7|(% style="width:102px" %)NRST|(% style="width:593px" %)Negative reset which can be connected to a button (Connected to +3V3)
78 -|(% style="width:96px" %)9|(% style="width:102px" %)PC1|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 2
79 -|(% style="width:96px" %)10|(% style="width:102px" %)PC2|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 2
80 -|(% style="width:96px" %)11|(% style="width:102px" %)PC3|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 4
81 -|(% style="width:96px" %)12|(% style="width:102px" %)PA0|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 4
82 -|(% style="width:96px" %)13|(% style="width:102px" %)PA1|(% style="width:593px" %)Analog signal: Oil temperature sensor right
83 -|(% style="width:96px" %)14|(% style="width:102px" %)PA2|(% style="width:593px" %)Analog signal: Air temperature sensor
84 -|(% style="width:96px" %)15|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
85 -|(% style="width:96px" %)16|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
86 -|(% style="width:96px" %)17|(% style="width:102px" %)PA3|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 1
87 -|(% style="width:96px" %)18|(% style="width:102px" %)PA4|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 1
88 -|(% style="width:96px" %)19|(% style="width:102px" %)PA5|(% style="width:593px" %)Analog signal: Cooling pressure sensor number 3
89 -|(% style="width:96px" %)20|(% style="width:102px" %)PA6|(% style="width:593px" %)Analog signal: Cooling temperature sensor number 3
90 -|(% style="width:96px" %)21|(% style="width:102px" %)PA7|(% style="width:593px" %)Analog signal: Oil temperature sensor left
91 -|(% style="width:96px" %)22|(% style="width:102px" %)PC4|(% style="width:593px" %)Analog signal: Suspension displacement sensor right
92 -|(% style="width:96px" %)23|(% style="width:102px" %)PC5|(% style="width:593px" %)Analog signal: Suspension displacement sensor left
93 -|(% style="width:96px" %)27|(% style="width:102px" %)VSSA|(% style="width:593px" %)Voltage source: Ground
94 -|(% style="width:96px" %)28|(% style="width:102px" %)VREF+|(% style="width:593px" %)Voltage reference (connected to +3V3)
95 -|(% style="width:96px" %)29|(% style="width:102px" %)VDDA|(% style="width:593px" %)Voltage source: Power (+3V3)
96 -|(% style="width:96px" %)31|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
97 -|(% style="width:96px" %)32|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
98 -|(% style="width:96px" %)34|(% style="width:102px" %)PB12|(% style="width:593px" %)CAN-BUS 2: Rxd
99 -|(% style="width:96px" %)35|(% style="width:102px" %)PB13|(% style="width:593px" %)CAN-BUS 2: Txd
100 -|(% style="width:96px" %)38|(% style="width:102px" %)PC6|(% style="width:593px" %)Signal Output: Blue status LED
101 -|(% style="width:96px" %)45|(% style="width:102px" %)PA11|(% style="width:593px" %)CAN-BUS 2: Rxd
102 -|(% style="width:96px" %)46|(% style="width:102px" %)PA12|(% style="width:593px" %)CAN-BUS 2: Txd
103 -|(% style="width:96px" %)47|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
104 -|(% style="width:96px" %)48|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
105 -|(% style="width:96px" %)49|(% style="width:102px" %)PA13|(% style="width:593px" %)Programming Pins: SWDIO
106 -|(% style="width:96px" %)50|(% style="width:102px" %)PA14|(% style="width:593px" %)Programming Pins: SWCLK
107 -|(% style="width:96px" %)63|(% style="width:102px" %)VSS|(% style="width:593px" %)Voltage source: Ground
108 -|(% style="width:96px" %)64|(% style="width:102px" %)VDD|(% style="width:593px" %)Voltage source: Power (+3V3)
109 109  
110 110  
111 -
112 112  == Air Temperature Sensor ==
113 113  
114 114  The air temperature sensor will be used to have a dynamic reference setpoint for the cooling system. This could reduce the current draw from the low voltage system compared to having a fixed reference point. This is because the regulator will not try to cool the water to a temperature lower than the ambient temperature. The sensor works as a resistor which varies depending on its temperature. Where in this case, the resistance lowers when the temperature increases (NTC). To make the microcontroller able to measure the changes in resistance, the thermistor is put into a voltage divider circuit.
... ... @@ -196,9 +196,9 @@
196 196  
197 197  where:
198 198  
199 -* {{mathjax}}\(x\){{/mathjax}}= The mechanical placement excluding the dead length (178mm).
196 +* {{mathjax}}\(x\){{/mathjax}} = The mechanical placement excluding the dead length (178mm).
200 200  * {{mathjax}}\(V_s\){{/mathjax}}= The supply voltage of the linear potentiometer, in this case it is 3.3 {{mathjax}}\(V\){{/mathjax}}.
201 -* {{mathjax}}\(V_{out}\){{/mathjax}}= The output voltage of the linear potentiometer. ranging from 0.033{{mathjax}}\(V\){{/mathjax}} to 3.267{{mathjax}}\(V\){{/mathjax}}.
198 +* {{mathjax}}\(V_{out}\){{/mathjax}} = The output voltage of the linear potentiometer. ranging from 0.033{{mathjax}}\(V\){{/mathjax}} to 3.267{{mathjax}}\(V\){{/mathjax}}.
202 202  
203 203  === Filtering ===
204 204