267 267  
268 268  where:
269 269  
270 -* {{mathjax}}\(Q\){{/mathjax}}=
271 -* {{mathjax}}\(R_0\){{/mathjax}}=
272 -* {{mathjax}}\(R_T\){{/mathjax}}=
270 +* {{mathjax}}\(Q\){{/mathjax}} = Waterflow through the equivalent orifice
271 +* {{mathjax}}\(C_D \cdot A_D\){{/mathjax}} = practical cross section of the orifice
272 +* {{mathjax}}\(\Delta P\){{/mathjax}} = Pressure difference between the two pressure sensors
273 +* {{mathjax}}\(\rho\){{/mathjax}} = Density of the cooling liquid
273 273  
275 +The sensor used on the AR26 car is the [[Bosch Motorsport PST-F 1>>https://www.bosch-motorsport.de/content/downloads/Raceparts/Resources/pdf/Data%20Sheet_70496907_Pressure_Sensor_Combined_PST-F_1.pdf]] and has the following transfer function for the output voltages based on pressure and temperature.
274 274  
277 +=== Pressure sensor ===
275 275  
279 +The pressure sensor build into the PST-F 1 has an supply voltage of 5 volts and has a output voltage range of 0.5 to 4.5 volts. The following formula shows the pressure based on the output voltage.
276 276  
277 277  
282 +
278 278  = Bill of Materials =
279 279  
280 280  == Circuit Board ==